-40%

GM328A Transistor Tester Diode Capacitance Inductance ESR Volt Frequency Meter

$ 6.82

Availability: 34 in stock
  • Marke: Markenlos
  • Condition: New
  • Brand: Unbranded
  • select: Russian

    Description

    Visit store
    Items for sale
    About us
    Product Details
    Product features:
    Digital LCD display, easy to read, can display measurement data and graphics
    Rotary switch control, easy to use for key measurement
    Press and hold the test button to exit the frequency measurement function. The frequency measurement range is from 1Hz to above 1MHz. When the measured frequency is lower than 25KHz, the cycle is displayed
    Square wave generator, with multi gear square wave frequency selectable. Rotate the left or right test button to switch to different square wave frequencies, and long press the test button to exit the square wave generator
    Pulse signal generator, turn left or right test button to adjust the pulse duty cycle from 1% to 99%. Press and hold the test button to exit the pulse signal generator
    Use 5V Type-c power supply interface for power supply, and customers can also weld 9V battery interface for power supply
    Automatic shutdown, shutdown current is only about 20nA
    Note: Before testing the capacitor, first discharge the capacitor, and then insert it into the test base for measurement, otherwise the microcontroller of the tester may be damaged.
    Input voltage: DC5V
    Working voltage: about 30mA,
    Control of transistor tester
    The tester is controlled by a rotary encoder switch,
    The rotary encoder switch can be operated in 6 ways: short press, long press, left rotation, right rotation, press and hold left rotation, press and hold right rotation.
    Press once in the shutdown state to turn on the power and start the test.
    If no device is detected after one test. Press and hold the switch or rotate the switch left and right to enter the function menu. After entering the function menu, the left or right switch can be selected above or below the menu item. To enter a function item, press the switch briefly. When you need to exit from a function, press and hold the switch.
    Calibration:
    The tester calibration is used to eliminate the error of its own components and make the final test results more accurate. Calibration is divided into quick calibration and full function calibration.
    Operation method for quick calibration: short circuit the three test points TP1, TP2 and TP3 with wires, then press the test button, and observe the screen at the same time. The screen color will become white on a black background, and the prompt message "Selftest mode..?" will appear After that, press the test button to enter the fast calibration process; If the prompt "Self test mode..?" appears After that, if no key is pressed within 2 seconds, a normal test process will be conducted, and the resistance values of the wires shorting TP1, TP2, and TP3 test points will be displayed finally. After entering the quick calibration process, some data will appear on the screen, regardless. Wait until a flashing string appears on the screen
    “isolate Probes!” After that, remove the wires shorting TP1, TP2 and TP3. The quick calibration is completed until the string "Test End" appears on the screen. For the first calibration, use the full function calibration mode.
    Full function calibration needs to be entered from the function menu, and another 220nf capacitor needs to be prepared. Full function calibration performs a more comprehensive calibration process and takes longer. After entering the function menu, turn the test button to the menu item "Selftest", and then press the test button to enter the full function calibration process. The flashing string "short Probes!" first appears on the screen, At this time, just like rapid calibration, use wires to short circuit the three test points and wait for the calibration process. The flashing string "isolate probes!" appears on the screen When the string "1 - | | - 3>100nf" appears on the screen, the prepared 220nf capacitor is installed on test points TP1 and TP3. Wait until the screen prompts "Test End", and the full function calibration process is completed.
    Package list:
    GM328A transistor tester* 1
    Payment Method
    Shipping Policy
    Returns & Refund Policy
    Feedback
    Payment Method
    EBAY Managed Payment.
    But we only
    Accept
    your
    Ebay Address
    , please Make sure it's 100% right.
    Payment must be received in 5 business days of auction closing.
    Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
    Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
    Shipping Policy
    1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
    2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
    3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.
    Returns & Refund Policy
    All package need to
    wait 30 days
    (US only n
    eed 7-10 days)
    ,
    Please take care it.Less than 30 days,we can't take a refund
    .
    If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it.
    If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.
    Feedback
    We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.