-40%

LCR-T4 LCR-T5 ATmega328 Digital Transistor Tester 12864 LCD Capacity Meter

$ 1.57

Availability: 590 in stock
  • Item must be returned within: 60 Days
  • Country/Region of Manufacture: China
  • EAN: Does Not Apply
  • Restocking Fee: No
  • MPN: Does Not Apply
  • All returns accepted: Returns Accepted
  • Brand: Unbranded/Generic
  • Return shipping will be paid by: Seller
  • Refund will be given as: Money Back
  • Condition: New
  • UPC: Does Not Apply

    Description

    Visit store
    Items for sale
    About us
    Product Details
    28 Pins Wide IC Test Socket
    28-Pin 28P Narrow Universal ZIF Test DIP IC Socket
    Package Included:
    1 x  28 Pin  Narrow Universal ZIF Test DIP IC Socket
    1 x  28 Pin  Wide Universal ZIF Test DIP IC Socket
    LCR-T4 Transistor Tester
    Attention please: the shell need DIY by yourself,battery isn't included.
    Clear Case
    LCR-T4 Transistor Tester+Clear Case
    LCR-T4 Transistor Tester
    1,2013 latest M328 version of the software ,more functions.Chip: Atmega328
    2.128*64 big Backlight LCD display,only 2mA when stand by.
    3,Using 9V battery (Not included)
    Test ranges:
    Inductors, capacitors , diodes, dual diode , mos, transistor, SCR , the regulator, LED tube , ESR,
    Resistance,Adjustable potentiometer
    Resistance :0.1 ohm resolution, maximum 50M ohm
    Capacitor :25pf -100,000 uf
    Inductors : 0.01mh-20H
    Function:
    1:Automatic detection of NPN and PNP transistors, n-channel and p-channel MOSFET,
    diode (including double diode), thyristor, transistor, resistor and capacitor and other components
    2: Automatic test the pin of a component, and display on the LCD
    3:Can detect the transistor, MOSFET protection diode amplification coefficient
    and the base to determine the emitter transistor forward biased voltage
    4: Measure the gate and gate capacitance of the MOSFET threshold voltage
    5:Use 12864 liquid crystal display with green backlight
    Case
    100% brand new and high quality
    Shape: Same as the picture show
    Clear Acrylic Housing :
    Suit For: LCR-T4 Transistor Tester Diode Triode Capacitance ESR Meter
    Note: It is DIY Parts, Not Assembled
    LCR-T4 Transistor Tester
    1,One -button operation, automatic shutdown .
    2,Only 20nA shutdown current.
    3,Automatically detect NPN, PNP bipolar transistors , N -channel and P -channel MOS FET,
    JFET , diodes , two diodes, thyristors small power unidirectional and bidirectional thyristor.
    4,Automatic identification components pin arrangement .
    5,Measuring bipolar transistor current amplification factor and base - emitter threshold voltage.
    6,Via the base - emitter threshold voltage and high current amplification factor to identify Darlington transistors.
    7,Can detect bipolar transistors and MOS transistors protection diodes.
    8,Measuring the gate MOS FET threshold voltage and the gate capacitance.
    9,Can simultaneously measure two resistors and resistor symbol is displayed.
    Displayed on the right with a decimal value of 4 .
    Resistance symbol on both sides shows the pin number.
    So you can measure the potentiometer.
    If the potentiometer wiper is not transferred to an extreme position ,
    we can distinguish the middle and both ends of the pin.
    10,Resistance measurement resolution is 0.1 ohms , 50M ohms can be measured .
    11,Can measure capacitanceCan measure capacitance of 30pF-100mF , resolution 1pF.
    12.2uF more capacitors can simultaneously measure the equivalent series resistance ESR values.
    The two can be displayed with a decimal value , resolution 0.01 ohms.
    13,Can be in the correct order and the diode symbol display two diodes , and gives the diode forward voltage.
    14.LED is detected as a diode forward voltage higher . Combo of the LED is identified as two diodes.
    15,Eeverse breakdown voltage is less than 4.5V Zener diode can be identified.
    16,Can measure a single diode reverse capacitance.
    If the bipolar transistor connected to the base and collector or emitter of a pin ,
    it can measure the collector or emitter junction reverse capacitance .
    18 can be obtained with a single measurement rectifier bridge connection.
    Notice: Before measuring capacitance , the capacitor must be discharged , otherwise very likely damage the meter .
    Package included:
    1*LCR-T4 Transistor Tester
    1*Clear case for LCR-t4
    LCR-T5 Transistor Tester
    Description:
    (Pls note:The battery is included in this package)
    1. Using ATmega328 microcontroller.
    2. 2x16-character LCD display the results.
    3. One button operation, automatic shut-off.
    4. Shutdown current is only 20nA, support for battery operation.
    5. Low-cost version without crystal, automatic shutdown. 1.05 k version of the ATmega168 or ATmega328 software in sleep mode when no measures to reduce energy consumption.
    6. Automatic detection PNP type and NPN bipolar transistors, N, P-channel MOSFET, JFET, diode, a double diode, thyristor SCR.
    7. Automatic detection of pin layout.
    8. Measuring current amplification factor of the bipolar transistor and the emitter threshold voltage.
    9. Darlington transistor amplification factor can be identified by the high threshold voltage and high current.
    10. For bipolar transistor, MOSFET protection diode test.
    11. measure the threshold voltage and the gate capacitance of the MOSFET.
    12. supports two resistance measurements and show the highest four numbers symbols and units. both ends of the resistor symbol is shown connected to the tester probes number (1-3). therefore, the potential can also be measured. If the potentiometer is set to its end, the tester can not distinguish between the middle and end of the pin.
    13. resistance measurement resolution is 0.1 ohms, the highest measured value 50 M ohms.
    14. can be detected and measured a capacitor. Maximum four numbers and units. Values can be from 25pF (8 MHz clock, 50pF @ 1 MHz clock) for 100mF. resolution up to 1 pF (@ 8 MHz clock).
    15. can be more valuable for 2 UF capacitor equivalent series resistance (ESR) measured capacitance value. resolution of 0.01 ohms and a two-digit numeric display. This feature requires at least 16 K Flash ATMEGA (ATmega168 or ATmega328).
    16. two diodes that can display symbols in the right direction. Furthermore, the forward voltage drop displayed.
    17. diode voltage drop detection LED is much higher than normal. Led two detected as double diode.
    18. Zener diode can be detected, if the reverse breakdown voltage is below 4.5 V. This will appear as two diodes, can only be determined by the voltage. probe across the diode symbol is the same, in such a case, it is possible to 700mV threshold voltage close to the true recognition anode of diode!
    19. **** this year to understand, do not turn on the ****
    if more than three diode type parts inspection, failure to follow to establish the display number diode another message. this will only happen if the diode is connected to all three probes and at least one diode. In this case, it must only connect the two probes and start the measurement again, one by one.
    20. Measure a single capacitance diode reverse. Bipolar transistors also able to measure, if connecting the base and the collector or emitter.
    Twenty one. only a measure to find full-bridge connection.
    twenty two. 25pF capacitor value is lower than usual undetectable, but with a diode in parallel or at least 25pF capacitor in parallel. In this case, you have to subtract part shunt capacitance values.
    twenty three. less than 2100 ohm resistance measure inductance, if you have at least 16 K ATMEGA flash. range from 0: 01mH 20 hours, but the accuracy is not good. the results of the measurements show only a single connection element.
    twenty-four. test time is of about two seconds, capacitance and inductance measurements will only take a long period of time.
    25. The software can be set to automatically turn off the power measurement of times before.
    26. built-in self-test function with selectable clock frequency of 50Hz signal control the precision and wait for the call (ATmega168 and ATmega328).
    27. of the equipment for measurement of internal resistance and optional calibration offset zero of the self-test capability of the output port (ATmega168 and ATmega328). need a 100nF 20 uF capacitor connected to compensate for the analog comparator between pins 1 and 3 of the offset voltage. this can reduce the measurement error over 40 uF capacitor. with the same voltage on the capacitor internal calibration reference voltage is found to internal adjustment reference measurement ADC gain.
    if the current test exceeds the holding current, the thyristor and triac it can be detected. but some current over the semiconductor tester capable of providing the SCR trigger and current triac. Available test current is only about 6mA! Note that all functions have only used single-chip program memory as more ATmega168.
    Package included:
    1*LCR-T5 ATmega328 Digital Transistor Tester 12864 LCD Capacity ESR Meter New
    Payment Method
    Shipping Policy
    Returns & Refund Policy
    Feedback
    Payment Method
    EBAY Managed Payment.
    But we only
    Accept
    your
    Ebay Address
    , please Make sure it's 100% right.
    Payment must be received in 5 business days of auction closing.
    Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
    Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
    Shipping Policy
    1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
    2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
    3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.
    Returns & Refund Policy
    All package need to
    wait 30 days
    (US only n
    eed 7-10 days)
    ,
    Please take care it.Less than 30 days,we can't take a refund
    .
    If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it.
    If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.
    Feedback
    We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.